Productions

A-D(ZN)2Y miniSLT-NMA-SJ-(GY12)

1- Optical fiber core ¹
2- Waterproof thixotropic jelly
3- PBT Tube
4- Non-metallic strength member (Glass yarn)
5- Ripcord
6- UV resistant polyethylene (HDPE) black outer jacket 
  Minimum Bending Radius
Operation 20 x cable Ø
Fixed 15 x cable Ø


  Temperature Range
Storage -40°C to +70°C Installation -30°C to +60°C
Transport -40°C to +70°C Operating -20°C to +70°C
  Test Standard Specified Value Acceptance Criteria
Maximum Installation Tension ²  IEC 60794-1-2-E1  1.0 x W(N), min. 1200 N  Fiber strain ≤ 0.33%
Maximum Operation Tension  IEC 60794-1-2-E1  0.5 x W(N), min. 600 N  Δα ≤ 0.05 dB, No fiber strain
Crush Strength  IEC 60794-1-2-E3  1500 N / 100 mm, max. 15 min.  Δα ≤ 0.05 dB, No damage
Impact  IEC 60794-1-2-E4  10 Nm, 3 impacts, R= 300 mm  Δα ≤ 0.05 dB after the test
Torsion  IEC 60794-1-2-E7  1 m. 100N, +/- 180°, 10 cycles  Δα ≤ 0.05 dB, No damage
Repeated Bending  IEC 60794-1-2-E6  R=20x D, 100 N, 35 cycles  No damage
Bending Radius  IEC 60794-1-2-E11  R=20x D, 4 turns, 3 cycles  Δα ≤ 0.05 dB, No damage
Temperature Cycling  IEC 60794-1-2-F1  -20°C to +70°C  Δα ≤ 0.05 dB/km
Waterproofness  IEC 60794-1-2-F5B  Sample= 3 m, water column= 1 m  No water leakage in 24 hours.
AVESCON
2025 PRODUCT CATALOGUE
Click here to view our product catalog.