A03VH-h / A05VH-h
Low voltage household appliances under less mechanical compulsion used in low temperature applications.| Min. bending radius | D≤12 ise 5D - D>12 ise 6D |
| Max. operating temperature | 60° |
| Max. short circuit temperature | 160° |
| Rated voltage | 300/300 V |
| AC test voltage | 2 kV |
| Flame propagation test on single cable | EN 60332-1 |
| Nominal Cross Section mm² | Overall Diameter mm approximately | Net Weight kg/km approximately | Conductor DC Resistance at (20°C) max. ohm/km | Current Carrying Capacity in |
|---|---|---|---|---|
| Air (A) | ||||
| A05V3V3-F ARCTIC (300/500 V) / 318A | ||||
| 2x0,75 | 6,3 | 57 | 26,0 | 6 |
| 2x1 | 6,6 | 65 | 19,5 | 10 |
| 2x1,50 | 7,8 | 91 | 13,3 | 16 |
| 2x2,5 | 9,1 | 130 | 7,98 | 25 |
| 2x4 | 10,6 | 184 | 4,95 | 32 |
| 3x0,75 | 6,7 | 68 | 26,0 | 6 |
| 3x1 | 7,0 | 78 | 19,5 | 10 |
| 3x1,5 | 8,1 | 106 | 13,3 | 16 |
| 3x2,5 | 9,9 | 163 | 7,98 | 25 |
| 3x4 | 11,3 | 227 | 4,95 | 32 |
| 4x0,75 | 7,3 | 82 | 26,0 | 6 |
| 4x1 | 7,9 | 100 | 19,5 | 10 |
| 4x1,5 | 9,0 | 134 | 13,3 | 16 |
| 4x2,5 | 10,8 | 200 | 7,98 | 25 |
| 4x4 | 12,3 | 280 | 4,95 | 32 |
| 5x0,75 | 8,1 | 102 | 26,0 | 6 |
| 5x1 | 8,6 | 120 | 19,5 | 10 |
| 5x1,5 | 10,0 | 166 | 13,3 | 16 |
| 5x2,5 | 12,0 | 249 | 7,98 | 25 |
| 5x4 | 13,9 | 355 | 4,95 | 32 |