ERVITAL LIHCH-TP FE180/PH120
In places where electro-magnetic interference and influence exists| Conductor | IEC-60228; DIN VDE 0295; EN 60228 Class 5 Stranded Electrolytic Bare Copper |
| Insulation | Cross-linked Ceramic Forming Polymer Compound |
| Colour Code | DIN 47100 |
| Stranding | Pairs in layers |
| Wrapping | Pes Tape + Glass Fibre Tape |
| Screen | Tinned Copper Braid |
| Sheath | EN 50290-2-27 HFFR Compound |
| CONDUCTOR RESISTANCE |
INSULATION RESISTANCE (min) |
MUTUAL CAPACITANCE |
CURRENT CARRYING CAPACITY |
BENDING RADIUS |
TEST VOLTAGE | OPERATING VOLTAGE | TEMPERATURE RANGE |
||
|---|---|---|---|---|---|---|---|---|---|
| mm² 0,22 0,34 0,50 0,75 1,0 1,5 2,5 |
Ω/km 79 56 39 26 19,5 13,3 7,98 |
MΩxkm 0,22mm²/0,34mm² = 200 ≥0,50mm² = 20 |
120nF/km | mm² 0,22 0,34 0,50 0,75 1,0 1,5 2,5 |
A 2,5 4,5 6,0 13 16 20 25 |
7,5x Cable Ø | 0.22mm²/0.34mm² = 1200V ≥0,50mm² = 2000V |
0,22mm²/0,34mm² = 250V ≥ 0,50mm² = 300/500V |
-40ºC~+70ºC |