U-D(ZN)H miniSLT-NMA-SHFJ-(GY12)
1- Optical fiber core ¹
2- Waterproof thixotropic jelly
3- PBT Tube
4- Non-metallic strength member (Glass yarn)
5- Ripcord
6- UV resistant halogen-free (LSOH) outer jacket
| |
Minimum Bending Radius |
| Operation |
20 x cable Ø |
| Fixed |
15 x cable Ø |
| |
Temperature Range |
| Storage |
-40°C to +70°C |
Installation |
-30°C to +60°C |
| Transport |
-40°C to +70°C |
Operating |
-20°C to +70°C |
| |
Test Standard |
Specified Value |
Acceptance Criteria |
| Maximum Installation Tension ² |
IEC 60794-1-2-E1 |
1.0 x W(N), min. 1200 N |
Fiber strain ≤ 0.33% |
| Maximum Operation Tension |
IEC 60794-1-2-E1 |
0.5 x W(N), min. 600 N |
Δα ≤ 0.05 dB, No fiber strain |
| Crush Strength |
IEC 60794-1-2-E3 |
1500 N / 100 mm, max. 15 min. |
Δα ≤ 0.05 dB, No damage |
| Impact |
IEC 60794-1-2-E4 |
10 Nm, 3 impacts, R= 300 mm |
Δα ≤ 0.05 dB after the test |
| Torsion |
IEC 60794-1-2-E7 |
1 m. 100N, +/- 180°, 10 cycles |
Δα ≤ 0.05 dB, No damage |
| Repeated Bending |
IEC 60794-1-2-E6 |
R=20x D, 100 N, 35 cycles |
No damage |
| Bending Radius |
IEC 60794-1-2-E11 |
R=20x D, 4 turns, 3 cycles |
Δα ≤ 0.05 dB, No damage |
| Temperature Cycling |
IEC 60794-1-2-F1 |
-20°C to +70°C |
Δα ≤ 0.05 dB/km |
| Waterproofness |
IEC 60794-1-2-F5B |
Sample= 3 m, water column= 1 m |
No water leakage in 24 hours |